UL Style & CSA Type |
Range | Conductor | Core | Insulation | Jacket | Overall Diameter mm |
Maximum Conductor Resistance Ω/km |
(VAC/min) Insulation Potential Strength |
||
Temp ℃ | Voltage V | AWG | NO./mm | Thickness mm |
Jacket Thickness |
|||||
UL 2841 | 80℃ | 30V | 30 | 7/0.10 | 2 | 0.38 | 1.14 | 4.78 | 354 | 500 |
3 | 4.95 | |||||||||
4 | 5.25 | |||||||||
80℃ | 30V | 28 | 7/0.127 | 2 | 0.38 | 1.14 | 4.95 | 223 | ||
3 | 5.15 | |||||||||
4 | 5.50 | |||||||||
80℃ | 30V | 26 | 7/0.16 | 2 | 0.38 | 1.14 | 5.20 | 140 | ||
3 | 5.40 | |||||||||
4 | 5.65 | |||||||||
80℃ | 30V | 24 | 11/0.16 | 2 | 0.38 | 1.14 | 5.35 | 87.6 | ||
3 | 5.60 | |||||||||
4 | 5.95 | |||||||||
80℃ | 30V | 22 | 17/0.16 | 2 | 0.38 | 1.14 | 5.75 | 55.4 | ||
3 | 5.95 | |||||||||
4 | 6.45 | |||||||||
80℃ | 30V | 20 | 26/0.16 | 2 | 0.38 | 1.14 | 6.00 | 34.6 | ||
3 | 6.35 | |||||||||
4 | 6.75 | |||||||||
80℃ | 30V | 18 | 41/0.16 | 2 | 0.38 | 1.14 | 6.55 | 21.8 | ||
3 | 6.90 | |||||||||
4 | 7.40 | |||||||||
80℃ | 30V | 16 | 65/0.16 | 2 | 0.38 | 1.14 | 7.20 | 13.7 | ||
3 | 7.50 | |||||||||
4 | 8.15 |