YI HUAN Precision power supply cords
Language: 中文版 ∷  英文版
YI HUAN PRECISION INDUSTRY CO.,LTD
Product Description
Conductor 40 AWG min, solid or stranded round, tinned or bare copper.
PVC Insulation and Jacket.
Rating temperature: 80°C.
Rating voltage: 30V.
Pass UL VW-1 & CSA FT1 vertical flame test.

Applications
Internal Wiring of Class 2 circuits in Electronic Equipment.

Structure & electrical properties
PVC Wire 2851​​
UL Style
&
CSA Type
Range Conductor Core Insulation Jacket Overall
Diameter
​mm
Maximum
Conductor
Resistance
Ω/km
(VAC/min)
Insulation
Potential
Strength
Temp ℃ Voltage V AWG NO./mm Thickness
mm
Jacket
Thickness
UL 2851 80℃ 30V 30 7/0.10 2 0.102 0.127 1.80 354 500
3 1.95
4 2.10
80℃ 30V 28 7/0.127 2 0.102 0.127 2.00 223
3 2.15
4 2.35
80℃ 30V 26 7/0.16 2 0.102 0.127 2.20 140
3 2.35
4 2.60
80℃ 30V 24 11/0.16 2 0.102 0.127 2.40 87.6
3 2.60
4 2.85
80℃ 30V 22 17/0.16 2 0.102 0.127 2.70 55.4
3 2.90
4 3.20
80℃ 30V 20 26/0.16 2 0.102 0.127 3.40 34.6
3 3.65
4 4.10
80℃ 30V 18 41/0.16 2 0.102 0.127 3.60 21.8
3 3.85
4 4.30
80℃ 30V 16 65/0.16 2 0.102 0.127 4.20 13.7
3 4.50
4 5.00