YI HUAN Precision power supply cords
Language: 中文版 ∷  英文版
YI HUAN PRECISION INDUSTRY CO.,LTD
Product Description
Conductor 30 AWG min, stranded.
PVC Insulation and Jacket.
Rated temperature: 80°C.
Rated voltage: not specified.
Pass UL VW-1 & CSA FT1 vertical flame test.


Applications
External interconnection of computers and electronic equipment.


Structure & electrical properties
PVC Wire 2345​​
UL Style
&
CSA Type
Range Conductor Core Insulation Jacket Overall
Diameter
mm
Maximum
Conductor
Resistance
Ω/km
(VAC/min)
Insulation
Potential
Strength
Temp ℃ Voltage V AWG NO./mm Thickness
mm
Jacket
Thickness
UL 2345 80℃ not specified 30 7/0.10 2 0.38 2.03 6.50 354 2000
3 6.70
4 7.00
80℃ not specified 28 7/0.127 2 0.38 2.03 6.60 223
3 6.80
4 7.70
80℃ not specified 26 7/0.16 2 0.38 2.03 6.80 140
3 7.00
4 7.40
80℃ not specified 24 11/0.16 2 0.38 2.03 7.10 87.6
3 7.30
4 7.70
80℃ not specified 22 17/0.16 2 0.38 2.03 7.30 55.4
3 7.60
4 8.00
80℃ not specified 20 26/0.16 2 0.38 2.03 7.70 34.6
3 8.00
4 8.50
80℃ not specified 18 41/0.16 2 0.38 2.03 8.10 21.8
3 8.40
4 9.00
80℃ not specified 16 65/0.16 2 0.38 2.03 8.70 13.7
3 9.10
4 9.70
80℃ not specified 14 41/0.251 2 0.38 2.03 9.50 8.62
3 9.90
4 10.65
80℃ not specified 12 65/0.251 2 0.38 2.03 10.55 5.43
3 11.10
4 11.90
80℃ not specified 10 105/0.251 2 0.38 2.03 11.80 3.409
3 12.35
4 13.35