YI HUAN Precision power supply cords
Language: 中文版 ∷  英文版
YI HUAN PRECISION INDUSTRY CO.,LTD
Product Description
Conductor: The tinned or bare standarded copper.
PVC Insulation and Jacket.
Rated temperature: 80°C.
Rated voltage: 150Vac.
Pass UL VW-1 & CSA FT1 vertical flame test.

Applications
Internal wiring of electronic equipment and appliances. Tags may indicate the following: "300 volts Peak for Electronic use only".

Structure & electrical properties
PVC Wire 2936​​
UL Style
&
CSA Type
Range Conductor Core Insulation Jacket Overall
Diameter
​mm
Maximum
Conductor
Resistance
Ω/km
(VAC/min)
Insulation
Potential
Strength
Temp ℃ Voltage V AWG NO./mm Thickness
mm
Jacket
Thickness
UL 2936 80℃ 150V 30 7/0.10 2 0.38 0.38 3.20 354 1500
3 3.40
4 3.70
80℃ 150V 28 7/0.127 2 0.38 0.38 3.40 223
3 3.60
4 3.95
80℃ 150V 26 7/0.16 2 0.38 0.38 3.60 140
3 3.80
4 4.20
80℃ 150V 24 11/0.16 2 0.38 0.38 3.80 87.6
3 4.10
4 4.40
80℃ 150V 22 17/0.16 2 0.38 0.38 4.20 55.4
3 4.50
4 4.90
80℃ 150V 20 26/0.16 2 0.38 0.38 4.50 34.6
3 4.80
4 5.30
80℃ 150V 18 41/0.16 2 0.38 0.38 5.00 21.8
3 5.35
4 5.85
80℃ 150V 16 65/0.16 2 0.38 0.38 5.60 13.7
3 6.00
4 6.60
80℃ 150V 14 41/0.251 2 0.38 0.38 6.40 8.62
3 6.85
4 7.55
80℃ 150V 12 65/0.251 2 0.38 0.38 7.30 5.43
3 7.80
4 8.65
80℃ 150V 10 105/0.251 2 0.38 0.38 8.60 3.409
3 0.76 9.90
4 0.76 10.90